Schedule 1
The limits of field strength and terminal voltage shall be as follows:
| Col. 1 | Col. 2 | Col. 3 | Col. 4 | Col. 5 | |
|---|---|---|---|---|---|
| Frequency Range in MHz | Maximum radiated field strength in microvolts per metre | Maximum terminal voltage in microvolts per metre | For protection of safety of life services | ||
| Exceeding | Not Exceeding | Maximum radiated field strength in microvolts per metre | Maximum terminal voltage in microvolts | ||
| 13·533 | 13·553 | 300,000 | 5,000,000 | ||
| 13·553 | 13·567 | unlimited | unlimited | ||
| 13·567 | 13·587 | 300,000 | 5,000,000 | ||
| 26·957 | 27·283 | unlimited | unlimited | ||
| 83·996 | 84·004 | 3,000,000 | |||
| 167·992 | 168·008 | 3,000,000 | |||
| 886 | 906 | 1,000,000 | |||
For all other frequencies in the ranges specified below, the limits of field strength and terminal voltage shall be as follows:
| Col. 1 | Col. 2 | Col. 3 | Col. 4 | Col. 5 | |
|---|---|---|---|---|---|
| 0·15 | 0·2 | 50 | 3,000 | 15 | 1,000 |
| 0·2 | 0·285 | 50 | 2,000 | 15 | 650 |
| 0·285 | 0·49 | 250 | 2,000 | 80 | 650 |
| 0·49 | 0·5 | 50 | 2,000 | 15 | 650 |
| 0·5 | 1·605 | 50 | 1,000 | 15 | 350 |
| 1·605 | 3·95 | 250 | 1,000 | 80 | 350 |
| 3·95 | 30·00 | 50 | 1,000 | 15 | 350 |
| 30·00 | 470·00 | 30 | 10 | ||
| 470·00 | 1,000·00 | 100 | 35 | ||