OpenLegislation

Regulation 8 Fixed client device transmission requirements

Original text. Later amendments are not shown.

(1)

A fixed client device must only operate within the frequency band 5925 to 7125 MHz in accordance with the limitations of operational parameters received (directly or indirectly) from an AFC system, or in the circumstances referred to in paragraph 2.

(2)

The circumstances referred to in paragraph (1) are where a fixed client device communicates with a standard power access point to obtain operational parameters from an AFC system while operating with a maximum power spectral density of 17 dBm per MHz and with a maximum EIRP over the nominal channel of 30 dBm.

(3)

A fixed client device must not, while operating in the 5925 to 7125 MHz frequency band connect to another fixed client device or a mobile client device.