Paragraph 1
Use of relevant stations and relevant apparatus for emission shall be limited to use –
(a)
on a frequency within a frequency band specified in table 1 below; and
(b)
where the maximum field strength of the emission does not exceed the limit specified in relation to that frequency band when measured at the distance specified in relation thereto.
TABLE 1
| Frequency Band (MHz) | Limit for maximum field strength (dBμ V/m) | Distance at which measurement taken (m) |
|---|---|---|
| 0.150 – 0.2835 | 34 | 100 |
| 0.5265 – 1.605 | 34 | 100 |
| 1.605 – 2.1735 | 48 | 100 |
| 2.1905 – 3.950 | 48 | 100 |
| 22.00 – 29.999 | 34 | 100 |
| 30.00 – 70.50 | 30 | 30 |
| 71.50 – 74.60 | 30 | 30 |
| 75.40 – 80.00 | 30 | 30 |
| 84.00 – 108.00 | 30 | 30 |
| 137.00 – 143.00 | 30 | 30 |
| 144.00 – 146.00 | 30 | 30 |
| 148.00 – 153.00 | 30 | 30 |
| 156.8375 – 225.00 | 30 | 30 |
| 400.00 – 405.50 | 30 | 30 |
| 406.50 – 450.00 | 30 | 30 |
| 453.00 – 464.00 | 30 | 30 |
| 467.00 – 960.00 | 30 | 30 |