The following data-quality objectives for the required accuracy of assessment methods, of minimum time coverage and of data capture of measurement are laid down to guide quality assurance programmes.

Sulphur dioxide, nitrogen dioxide and oxides of nitrogenParticulate matter and lead
Continuous measurement
Accuracy15%25%
Minimum data capture90%90%
Indicative measurement
Accuracy25%50%
Minimum data capture90%90%
Minimum time coverage14% (One measurement a week at random, evenly distributed over the year, or eight weeks evenly distributed over the year.)14% (One measurement a week at random, evenly distributed over the year, or eight weeks evenly distributed over the year.)
Modelling
Accuracy:
Hourly averages50%–60%
Daily averages50%
Annual averages30%50%
Objective estimation
Accuracy:75%100%