Paragraph 11
Test report.
Values for the following parameters are to be given in the test report for each of the detonation tests:
- (a)
the values actually measured for the outside diameter of the steel tube and for the wall thickness,
- (b)
the Brinell hardness of the steel tube,
- (c)
the temperature of the tube and the sample shortly before firing,
- (d)
the packing density (kg/m3) of the sample in the steel tube,
- (e)
the height of each lead cylinder after firing, specifying the corresponding cylinder number, and
- (f)
method of initiation employed for the booster charge.