OpenLegislation

Paragraph 10 Organic peroxidesI1

Northern Ireland Not yet in force

Changes not yet applied. Later legislation changes this provision in ways not yet written into the text below:

For the following goods—

  • UN 3113 ORGANIC PEROXIDE TYPE C, LIQUID, TEMPERATURE CONTROLLED*

  • UN 3114 ORGANIC PEROXIDE TYPE C, SOLID, TEMPERATURE CONTROLLED*

  • UN 3115 ORGANIC PEROXIDE TYPE D, LIQUID, TEMPERATURE CONTROLLED*

  • UN 3116 ORGANIC PEROXIDE TYPE D, SOLID, TEMPERATURE CONTROLLED*

  • UN 3117 ORGANIC PEROXIDE TYPE E, LIQUID, TEMPERATURE CONTROLLED*

  • UN 3118 ORGANIC PEROXIDE TYPE E, SOLID, TEMPERATURE CONTROLLED*

  • UN 3119 ORGANIC PEROXIDE TYPE F, LIQUID, TEMPERATURE CONTROLLED* (tert-Butyl peroxyacetate)

  • UN 3119 ORGANIC PEROXIDE TYPE F, LIQUID, TEMPERATURE CONTROLLED* (tert-Butyl peroxy-2-ethylhexanoate)

  • UN 3119 ORGANIC PEROXIDE TYPE F, LIQUID, TEMPERATURE CONTROLLED* (tert-Butyl peroxypivilate)

  • UN 3119 ORGANIC PEROXIDE TYPE F, LIQUID, TEMPERATURE CONTROLLED* (tert-Butyl peroxy-3, 3, 5-trimethylhexanoate)

  • UN 3119 ORGANIC PEROXIDE TYPE F, LIQUID, TEMPERATURE CONTROLLED* (Di (3, 5, 5-trimethyl-hexanoyl) peroxide)

  • UN 3119 ORGANIC PEROXIDE TYPE F, LIQUID, TEMPERATURE CONTROLLED*

  • UN 3120 ORGANIC PEROXIDE TYPE F, SOLID, TEMPERATURE CONTROLLED*

the methods of temperature control specified below shall be used—

(a)

where the maximum ambient temperature to be expected during carriage is at least 10 degrees centigrade below the control temperature, any of the methods specified in paragraph 8(5);

(b)

where the maximum ambient temperature to be expected during carriage does not exceed the control temperature by more than 30 degrees centigrade, one of the methods specified in paragraph 8(5)(b) to (e);

(c)

in all other cases, one of the methods specified in paragraph 8(5)(c) to (e).

Annotations

Commencement

I1

Sch. 4 para. 10 in operation at 1.7.1997, see reg. 1