OpenLegislation

Paragraph 3 I1

Northern Ireland

Changes not yet applied. Later legislation changes this provision in ways not yet written into the text below:

The operator of a vehicle or container which is carrying—

(a)

explosive substances in Division 1.1 and Compatibility Group C, D or G or in Division 1.2 and Compatibility Group G or in Division 1.3 and Compatibility Group C or G, which are free-flowing and powdery;

(b)

fireworks in Divisions 1.1, 1.2 or 1.3 and Compatibility Group G,

shall ensure that the floor of the vehicle or container respectively has a non-metallic surface or covering which is incapable of producing sparks.

Annotations

Commencement

I1

Sch. 2 para. 3 in operation at 1.12.1997, see reg. 1