OpenLegislation

Chapter Action levels – thermal effects

England, Wales and Scotland

Table AL3 – ALs for exposure to electromagnetic fields from 100 kHz to 300 GHz

Frequency rangeExternal electric field strength ALs (E) [Vm-1]Magnetic flux density ALs (B)[µT]Power density AL (S)[Wm-2]
100 kHz ≤ f < 1 MHz6.1 × 1022.0 × 106/f-
1 ≤ f < 10 MHz6.1 × 108/f2.0 × 106/f-
10 ≤ f < 400 MHz610.2-
400 MHz ≤ f < 2 GHz3 × 10-3 f1/21.0 × 10-5 f1/2-
2 ≤ f < 6 GHz1.4 × 1024.5 × 10-1-
6 ≤ f ≤ 300 GHz1.4 × 1024.5 × 10-150
Exposure levels not exceeding the ALs will be compliant with:

Up to 6 GHz: the health effect ELVs in Table ELV4

6 - 300 GHz: the health effect ELV in Table ELV6

The health effect ELV in Table ELV6
  1. 1Notes
  2. 2Notes
  3. 3Notes
  4. 4Notes
  5. 5Notes

Notes on Part 2

Commencement

I1

Sch. Pt. 2 in force at 1.7.2016, see reg. 1