Part 2 Conditions
Cables and cable protection
10
(1)
Within Work No. 5B the inter-platform cables must not, in total—
(a)
exceed 3 in number;
(b)
exceed 138 kilometres in length;
(c)
exceed 9 cable crossings;
(d)
have cable protection (including cable crossings) exceeding 286,808 square metres in area; or
(e)
have cable protection (including cable crossings) exceeding 260,234 cubic metres in volume.
(2)
The inter-platform cables within Work No. 5B which falls within the Dogger Bank Special Area of Conservation must not have cable protection exceeding 10% of the length of such cables, when combined with the offshore export cables, array cables and inter-platform cables authorised by the licences granted under Schedules 11 to 14A of the Order.