Paragraph 6 I1
Wind turbine generator foundation structures must be of 1 or more of the following foundation options: monopole, multi-leg or gravity base.
No wind turbine generator foundation structure employing a footing of driven piles may—
have more than 6 driven piles;
in the case of single-pile structures, have a pile diameter exceeding 12 metres or employ a hammer energy during installation exceeding 3,000 kilojoules;
in the case of structures with 2 or more piles, have a pile diameter exceeding 3.5 metres or employ a hammer energy during installation exceeding 2,300 kilojoules.
No wind turbine generator foundation may have—
a main supporting structure exceeding 61 metres in width;
a seabed footprint (excluding subsea scour protection) exceeding 2,376 square metres;
a seabed footprint (including subsea scour protection) exceeding 5,675 square metres.
The foundations for wind turbine generators must be in accordance with the wave reflection co-efficient values set out in Table 3.6 in Chapter 5, Appendix B (foundation characterisation study) of the environmental statement.
Annotations
Commencement
- I1
Sch. 8 para. 6 in force at 26.8.2015, see art. 1