Paragraph 5 I1
In relation to a wind turbine generator, each gravity base foundation must not have—
a diameter at the level of the seabed which is more than 60 metres;
a base height, where there is a flat base and a cylindrical shaft, which is more than 12 metres above the level of the seabed;
a base height, where there is a conical base, which is more than 2 metres above the level of the seabed;
a column diameter, where there is a flat or conical base, which is more than 9 metres at LAT.
In relation to a wind turbine generator, each suction caisson foundation must not have—
a diameter at the level of the seabed which is more than 30 metres;
a base height where there is a flat base, which is more than 5 metres above the level of the seabed;
a column diameter which is more than 9 metres at LAT.
In relation to a wind turbine generator, each jacket foundation must not have—
a width spacing between its legs at the level of the seabed which is more than 43.5 metres;
a pile diameter which is more than 4 metres in the case of pin piles or a suction caisson diameter which is more than 10 metres;
more than one pile per leg or more than one suction caisson per leg;
more than four legs.
In relation to a wind turbine generator, each monopile foundation forming part of the authorised development must not have a diameter which is more than 12 metres.
Annotations
Commencement
- I1
Sch. 1 Pt. 3 para. 5 in force at 29.8.2017, see art. 1