Paragraph 6 Detailed offshore design parametersI1
England, Wales and Scotland
(1)
In relation to a meteorological mast, each gravity base foundation must not have a footprint at the seabed which is more than 315 m2.
(2)
In relation to a meteorological mast, each suction caisson foundation must not have a footprint at the seabed which is more than 177 m2.
(3)
In relation to a meteorological mast, each jacket foundation must not have a footprint at the seabed which is more than 651 m2.
(4)
In relation to a meteorological mast, each monopile foundation must not have a footprint at the seabed which is more than 51 m2.
Annotations
Commencement
- I1
Sch. 1 Pt. 3 para. 6 in force at 22.4.2022, see art. 1(2)