Paragraph 12 Weighted average energy consumptionI1
England, Wales and Scotland
The weighted average energy consumption per 100 drying cycles of the electric mains-operated household tumble dryer is calculated as follows and rounded to the nearest integer—
The weighted average energy consumption per 100 drying cycles of the gas-fired tumble dryer is calculated as follows and rounded to the nearest integer—
where—
“Eg dry” is the gas consumption of the eco programme at full load, in kWh and rounded to two decimal places;
“Eg dry1/2” is the gas consumption of the eco programme at partial load, in kWh and rounded to two decimal places;
“Eg dry,a” is the auxiliary electricity consumption of the eco programme at partial load, in kWh and rounded to two decimal places;
“Eg dry1/2,a” is the auxiliary electricity consumption of the eco programme at partial load, in kWh and rounded to two decimal places.
Annotations
Commencement
- I1
Sch. 4 para. 12 in force at 10.4.2026, see reg. 2(1)(f)