Paragraph 1 I1
England, Wales and Scotland
For an electric household tumble dryer, the technical documentation must include the following information—
a general description of the model allowing it to be unequivocally and easily identified;
references to the designated standards applied or other measurement standards used;
specific precautions to be taken when the model is assembled, installed, maintained or tested;
the details and the results of calculations made in accordance with Schedule 4;
testing conditions, where they are not described sufficiently in the references provided pursuant to sub-paragraph (b);
equivalent models, if any, including model identifiers;
the values for the technical parameters set out in Table 1, which are considered as the declared values for the purpose of the verification procedure set out in Schedule 13;
a description of the disassembly steps for each priority part, including the tools and fasteners needed at each step, if any, except where the supplier chooses not to include this information;
the repair and maintenance information laid down in paragraph 14 of Schedule 2, except where the supplier chooses not to include this information.
Table 1: Declared technical parameters for electric household tumble dryers
| PARAMETER | UNIT | VALUE |
|---|---|---|
| Rated capacity for the eco programme, at 0.5 kg intervals (c) | kg | X.X |
| Energy consumption of the eco programme at full load (Edry) | kWh/drying cycle | X.XX |
| Energy consumption of the eco programme at partial load (Edry,½) | kWh/drying cycle | X.XX |
| Weighted energy consumption of the eco programme (EtC) | kWh/drying cycle | X.XX |
| Standard energy consumption of the eco programme (SEC) | kWh/drying cycle | X.XX |
| EEI | - | X.X |
| Programme duration for the eco programme at full load (Tdry) | h:min | X:XX |
| Programme duration for the eco programme at partial load (Tdry½) | h:min | X:XX |
| Weighted programme duration for the eco programme (Tt) | h:min | X:XX |
| Average condensation efficiency of the eco programme at full load (Cdry) (if applicable) | % | XX |
| Average condensation efficiency of the eco programme at partial load (Cdry½) (if applicable) | % | XX |
| Weighted condensation efficiency of the eco programme (Ct) (if applicable) | % | XX |
| Acoustic airborne noise emission during the eco programme | dB(A) with respect to 1 pW | X |
| Power consumption in off mode (Po) (if applicable) | W | X.XX |
| Power consumption in standby mode (Psm) (if applicable) | W | X.XX |
| Does ‘standby mode’ include the display of information? | - | Yes/No |
| Power consumption in ‘standby mode’ in condition of networked standby (Pnsm) (if applicable) | W | X.XX |
| Power consumption in delay start (Pds) (if applicable) | W | X.XX |
| Repairability index | - | X.XX |
Annotations
Commencement
- I1
Sch. 5 para. 1 in force at 10.4.2026, see reg. 2(1)(f)