OpenLegislation

Paragraph 7

Original text. Later amendments are not shown.

The maximum allowable electricity consumption (Emax, expressed in kWh per 24 hours calculated to two decimal places) for an appliance type with adjusted volume Vadj shall be defined by the following equations for each appliance category:

CategoryDescriptionEmax (kWh/24 h)
1Refrigerator without low temperature compartment(0.207 × Vadj + 218)/365
2Refrigerator/chiller with compartment at 5°C and/or 12°C(0.207 × Vadj + 218)/365
3Refrigerator with no-star low temperature compartment(0.207 × Vadj + 218)/365
4Refrigerator with low temperature compartment (*)(0.557 × Vadj + 166)/365
5Refrigerator with low temperature compartment (**)(0.402 × Vadj + 219)/365
6Refrigerator with low temperature compartment (***)(0.573 × Vadj + 206)/365
7Refrigerator/freezer, with freezer compartment (****)(0.697 × Vadj + 272)/365
8Food freezer, upright(0.434 × Vadj + 262)/365
9Food freezer, chest(0.480 × Vadj + 195)/365

For refrigerators/freezers with more than two doors, or other appliances not covered above, the maximum allowable electricity consumption (Emax) shall be determined by the temperature and the star rating of the compartment with the lowest temperature, as follows:

Temperature of the coldest compartmentCategoryEmax (kWh/24 hours)
> − 6°C1/2/3(0.207 × Vadj + 218)/365
≤ − 6°C (*)4(0.557 × Vadj + 166)/365
≤ − 12°C (**)5(0.402 × Vadj + 219)/365
≤ − 18°C (***)6(0.573 × Vadj + 206)/365
≤ − 18°C (****)7(0.697 × Vadj + 272)/365