OpenLegislation

Paragraph 1

The information sheet shall contain the information specified below. The information may be given in the form of a table covering a number of models supplied by the same supplier (in which case it shall be given in the order specified) or given close to the description of the regulated appliance.

(1)

Supplier's trade mark.

(2)

Supplier's model identifier.

For “split and multi-split units” the model identifier of the indoor and of the outdoor elements of the combination to which the figures quoted below apply.

(3)

The energy efficiency class of the model, determined in accordance with Schedule 3 and expressed as “Energy efficiency class on a scale of A (more efficient) to G (less efficient)”. Where this information is provided in a table, it may be expressed by other means provided it is clear that the scale is from A (more efficient) to G (less efficient).

(4)

Where the information is provided in a table, and where some of the regulated appliances listed in the table have been granted a “European Union eco-label” under Regulation (EC) No 1980/2000, the row heading shall state “European Union eco-label” and the entry shall consist of a copy of the eco-label. This provision is without prejudice to any requirements under the Community eco-label award scheme.

(5)

The indicative annual consumption of energy based on an average use of 500 hours per year, determined in accordance with the test procedures of the harmonised standard (conditions T1 “moderate”), as defined in Note V to paragraph 2 of Schedule 1.

(6)

The cooling output defined as the cooling capacity in kW of the regulated appliance in cooling mode at full load, determined in accordance with the test procedures of the harmonised standard (conditions T1 “moderate”), as defined in Note VI to paragraph 2 of Schedule 1.

(7)

The EER (energy efficiency ratio) of the regulated appliance in cooling mode at full load, determined in accordance with the test procedures of the harmonised standard (conditions T1 “moderate”).

(8)

The type of regulated appliance: cooling only, cooling/heating.

(9)

The cooling mode: air cooled, water cooled.

(10)

In the case of regulated appliances with heating capability:

(a)

the heat output defined as heating capacity in kW of the regulated appliance in heating mode at full load, determined in accordance with the test procedures of the harmonised standard (conditions T1 + 7C), as defined in Note X to paragraph 2 of Schedule 1;

(b)

the heating mode energy efficiency class in accordance with Schedule 3, expressed on a scale of A (higher) to G (lower), determined in accordance with the test procedures of the harmonised standard (conditions T1 + 7C), as defined in Note XI to paragraph 2 of Schedule 1. If the regulated appliance heating capability is provided by a resistive element then the COP (coefficient of performance) shall have the value of 1.

(11)

Noise during standard function, where applicable M1.

(12)

Suppliers may include in addition the information in sub-paragraphs (5) to (8) in respect of other test conditions determined in accordance with the test procedures of the harmonised standard.

Annotations

Marginal citations

M1

Where noise information is provided, the Household Appliances (Noise Emission) Regulations 1990 apply (S.I. 1990/161 as amended by S.I. 1994/1386, 2004/693).