OpenLegislation

Paragraph 28 FormulaF1

(1)

The following formula is to be used to calculate the emission concentration at the standard percentage oxygen concentration—

ES=21-OS21-OM×EM
(2)

In sub-paragraph (1)—

  • “ES” means calculated emission concentration at the standard percentage oxygen concentration,

  • “EM” means measured emission concentration,

  • “OS” means standard oxygen concentration,

  • “OM” means measured oxygen concentration.

Annotations

Textual amendments

F1

Sch. 22 inserted (1.11.2025) by The Environmental Authorisations (Scotland) Amendment Regulations 2025 (S.S.I. 2025/165), reg. 1(2), sch. 13 (with sch. 23)