Paragraph 22 Requirements in respect of safety-related devices
Safety devices shall function independently of any measurement or control devices, or both measurement and control devices required for operation.
As far as possible, failure of a safety device shall be detected sufficiently rapidly by appropriate technical means to prevent dangerous situations from occurring.
The fail-safe principle is to be applied in general.
Safety-related switching shall in general directly actuate the relevant control devices without intermediate software command.
In the event of a safety device failure, equipment or protective systems or both shall wherever possible, be secured.
Emergency stop controls of safety devices shall, as far as possible, be fitted with restart lockouts. A new start command may take effect on normal operation only after the restart lockouts have been intentionally reset.