Division 2.3.1 Leaching limit values
United Kingdom
The following leaching limit values apply to granular hazardous waste acceptable at landfills for non-hazardous waste, calculated at L/S = 2 and 10 l/kg for total release and directly expressed in mg/l for C0 ( the first eluate of percolation test at L/S = 0,1 l/kg). Granular wastes include all wastes that are not monolithic. F1The appropriate authority shall determine which of the test methods and corresponding limit values should be used.
| Components | L/S = 2 l/kg | L/S = 10 l/kg | C0 (percolation test) |
|---|---|---|---|
| mg/kg dry substance | mg/kg dry substance | mg/l | |
* If the waste does not meet these values for DOC at its own pH, it may alternatively be tested at L/S = 10 l/kg and a pH of 7,5-8,0. The waste may be considered as complying with the acceptance criteria for DOC, if the result of this determination does not exceed 800 mg/kg (A draft method based on prEN 14429 is available). ** The values for TDS can be used alternativelyto the values for sulphate and chloride. | |||
| As | 0,4 | 2 | 0,3 |
| Ba | 30 | 100 | 20 |
| Cd | 0,6 | 1 | 0,3 |
| Cr total | 4 | 10 | 2,5 |
| Cu | 25 | 50 | 30 |
| Hg | 0,05 | 0,2 | 0,03 |
| Mo | 5 | 10 | 3,5 |
| Ni | 5 | 10 | 3 |
| Pb | 5 | 10 | 3 |
| Sb | 0,2 | 0,7 | 0,15 |
| Se | 0,3 | 0,5 | 0,2 |
| Zn | 25 | 50 | 15 |
| Chloride | 10 000 | 15 000 | 8 500 |
| Fluoride | 60 | 150 | 40 |
| Sulphate | 10 000 | 20 000 | 7 000 |
| DOC f1 | 380 | 800 | 250 |
| TDS f2 | 40 000 | 60 000 | — |
F2The appropriate authority shall set criteria for monolithic waste to provide the same level of environmental protection given by the above limit values.
Annotations
Textual amendments
- F1
Words in Annex section 2.3.1 substituted (31.12.2020) by The Waste (Miscellaneous Amendments) (EU Exit) Regulations 2019 (S.I. 2019/620), regs. 1(2)(b), 15(7)(d)(vi)(aa); 2020 c. 1, Sch. 5 para. 1(1)
- F2
Words in Annex section 2.3.1 substituted (31.12.2020) by The Waste (Miscellaneous Amendments) (EU Exit) Regulations 2019 (S.I. 2019/620), regs. 1(2)(b), 15(7)(d)(vi)(bb); 2020 c. 1, Sch. 5 para. 1(1)
Footnotes
- f1
*
If the waste does not meet these values for DOC at its own pH, it may alternatively be tested at L/S = 10 l/kg and a pH of 7,5-8,0. The waste may be considered as complying with the acceptance criteria for DOC, if the result of this determination does not exceed 800 mg/kg (A draft method based on prEN 14429 is available).
- f2
**
The values for TDS can be used alternativelyto the values for sulphate and chloride.
Notes on Division 2
Textual amendments
- F1
Words in Annex section 2 substituted (31.12.2020) by The Waste (Miscellaneous Amendments) (EU Exit) Regulations 2019 (S.I. 2019/620), regs. 1(2)(b), 15(7)(d)(i)(aa); 2020 c. 1, Sch. 5 para. 1(1)
- F2