In addition to the leaching limit values under section 2.3.1, granular wastes must meet the following additional criteria:

ParameterValue
*

If this value is not achieved, a higher limit value may be admitted by the competent authority, provided that the DOC value of 800 mg/kg is achieved at L/S = 10 l/kg, either at the material's own pH or at a pH value between 7,5 and 8,0.

TOC (total organic carbon)5 % f1
pHMinimum 6
ANC (acid neutralisation capacity)Must be evaluated

F1The appropriate authority must set criteria to ensure that the waste will have sufficient physical stability and bearing capacity.

The appropriate authority shall set criteria to ensure that hazardous monolithic wastes are stable and non-reactive before acceptance in landfills for non-hazardous waste.

Annotations

Textual amendments

F1

Words in Annex section 2.3.2 substituted (31.12.2020) by The Waste (Miscellaneous Amendments) (EU Exit) Regulations 2019 (S.I. 2019/620), regs. 1(2)(b), 15(7)(d)(vii); 2020 c. 1, Sch. 5 para. 1(1)

Footnotes

f1

*

If this value is not achieved, a higher limit value may be admitted by the competent authority, provided that the DOC value of 800 mg/kg is achieved at L/S = 10 l/kg, either at the material's own pH or at a pH value between 7,5 and 8,0.

Notes on Division 2

Textual amendments

F1

Words in Annex section 2 substituted (31.12.2020) by The Waste (Miscellaneous Amendments) (EU Exit) Regulations 2019 (S.I. 2019/620), regs. 1(2)(b), 15(7)(d)(i)(aa); 2020 c. 1, Sch. 5 para. 1(1)

F2

Words in Annex section 2 substituted (31.12.2020) by The Waste (Miscellaneous Amendments) (EU Exit) Regulations 2019 (S.I. 2019/620), regs. 1(2)(b), 15(7)(d)(i)(bb); 2020 c. 1, Sch. 5 para. 1(1)