Division 2 F1
United Kingdom
The apparatus shall be equipped with 16 2 MHz ultrasonic transducers (Carometec A/S), with an operating distance between transducers of 25 mm. The ultrasonic data shall comprise measurements of back-fat thickness, muscle thickness and related parameters. The results of the measurements shall be converted into estimates of the percentage of lean meat by using a computer.