Division Part 4 FULLY AUTOMATIC ULTRASONIC EQUIPMENT (AutoFOM 1)
United Kingdom
- 1Division 1
- 2The apparatus shall be equipped with 16 ultrasonic transducers, 2MHz (Krautkrämer, SFK 2 NP or similar) with a distance of 25 mm between each transducer.
- 3The lean meat content of the carcase shall be calculated on the basis of 127 individual measuring points according to the following formula
- 4The description of the measurement points and the description of the statistical method are laid down in the Danish Protocol, Part II, submitted to the Commission under the terms of Article 3(3) of Commission Regulation (EEC) No 2967/85.