OpenLegislation

Division 4.4 Emissions to water

United Kingdom

Original text. Later amendments are not shown.

After waste water treatment, whether on-site or off-site, the following parameters shall not exceed the following limits:

The ‘Fe’ parameter is applicable to all the processed products ‘with the exclusion of ceramic tiles’.

ParameterLimitTest methods
Suspended solid emission to water40 mg/lISO 5667-17
Cd emission to water0,015 mg/lISO 8288
Cr(VI) emission to water0,15 mg/lISO 11083
Fe emission to waterf1 1,5 mg/lISO 6332
Pb emission to water0,15 mg/lISO 8288

Assessment and verification: the applicant shall provide appropriate documentation and test reports showing compliance with this criterion.

Annotations

Footnotes

f1

The ‘Fe’ parameter is applicable to all the processed products ‘with the exclusion of ceramic tiles’.