Division 4.4 Emissions to water
United Kingdom
After waste water treatment, whether on-site or off-site, the following parameters shall not exceed the following limits:
| The ‘Fe’ parameter is applicable to all the processed products ‘with the exclusion of ceramic tiles’. | ||
| Parameter | Limit | Test methods |
|---|---|---|
| Suspended solid emission to water | 40 mg/l | ISO 5667-17 |
| Cd emission to water | 0,015 mg/l | ISO 8288 |
| Cr(VI) emission to water | 0,15 mg/l | ISO 11083 |
| Fe emission to waterf1 | 1,5 mg/l | ISO 6332 |
| Pb emission to water | 0,15 mg/l | ISO 8288 |
Assessment and verification: the applicant shall provide appropriate documentation and test reports showing compliance with this criterion.
Annotations
Footnotes
- f1
-
The ‘Fe’ parameter is applicable to all the processed products ‘with the exclusion of ceramic tiles’.