OpenLegislation

Division 73

United Kingdom

Original text. Later amendments are not shown.

BAT is to control SOX emissions from the melting furnace by using one or a combination of the following techniques:

A description of the techniques is given in Section 1.10.3.

Techniquef1 Applicability

(i)

Selection of raw materials for the batch formulation with a low content of sulphur

The technique is generally applicable within the constraints of the availability of raw materials

(ii)

Dry or semi-dry scrubbing, in combination with a filtration system

The technique is generally applicable

(iii)

Use of low sulphur content fuels

The applicability may be limited by the constraints associated with the availability of low sulphur fuels, which may be impacted by the energy policy of the Member State

Table 63

BAT-AELs for SOX emissions from the melting furnace in the frits sector

The conversion factors of 5 × 10–3 and 7,5 × 10–3 have been used; however, the values indicated in the table may have been approximated. A case-by-case conversion factor may have to be applied based on the type of combustion (see Table 2).

ParameterBAT-AEL
mg/Nm3 kg/tonne melted glassf2
SOX, expressed as SO2 < 50 – 200< 0,25 – 1,5

Annotations

Footnotes

f1

A description of the techniques is given in Section 1.10.3.

f2