OpenLegislation

Division 3.6 Default values for SPF and Qusable for heat pumps

United Kingdom

Original text. Later amendments are not shown.

The default values for HHP and SPF (SCOPnet) for electrically driven heat pumps are as set out in the table below:

Table 1

Default values for HHP and SPF (SCOPnet) for electrically driven heat pumps

Climate conditions
Warmer climateAverage climateColder climate
Heat Pump Energy source:Energy source and distribution mediumHHP SPF(SCOPnet)HHP SPF(SCOPnet)HHP SPF(SCOPnet)
Aerothermal energyAir-Air1 2002,71 7702,61 9702,5
Air-Water1 1702,71 6402,61 7102,5
Air-Air (reversible) X1120 2,77102,61 9702,5
Air-Water (reversible) 120 2,76602,61 7102,5
Exhaust Air-Air7602,76602,66002,5
Exhaust Air-Water7602,76602,66002,5
Geothermal energyGround-Air1 3403,22 0703,22 4703,2
Ground-Water1 3403,52 0703,52 4703,5
Hydrothermal heatWater-Air1 3403,22 0703,22 4703,2
Water-Water1 3403,52 0703,52 4703,5

The default values for HHP and SPF (SPERnet) for heat pumps driven by thermal energy are as set out in the table below:

Table 2

Default values for HHP and SPF (SPERnet) for heat pumps driven by thermal energy

Climate conditions
Warmer climateAverage climateColder climate
Heat Pump Energy source:Energy source and distribution mediumHHP SPF(SPERnet)HHP SPF(SPERnet)HHP SPF(SPERnet)
Aerothermal energyAir-Air1 2001,21 7701,21 9701,15
Air-Water1 1701,21 6401,21 7101,15
Air-Air (reversible) 120 1,27101,21 9701,15
Air-Water (reversible) 120 1,26601,21 7101,15
Exhaust Air-Air7601,26601,26001,15
Exhaust Air-Water7601,26601,26001,15
Geothermal energyGround-Air1 3401,42 0701,42 4701,4
Ground-Water1 3401,62 0701,62 4701,6
Hydrothermal heatWater-Air1 3401,42 0701,42 4701,4
Water-Water1 3401,62 0701,62 4701,6

The default values set out in Tables 1 and 2 above are typical for the segment of heat pumps with a SPF above the minimum threshold, meaning that heat pumps with SPF below 2,5 have not been taken into consideration when the typical values have been establishedf1.

Annotations

Editorial notes

X1

Substituted by Corrigendum to Commission Decision 2013/114/EU of 1 March 2013 establishing the guidelines for Member States on calculating renewable energy from heat pumps from different heat pump technologies pursuant to Article 5 of Directive 2009/28/EC of the European Parliament and of the Council (Official Journal of the European Union L 62 of 6 March 2013).

Footnotes

f1

This implies that Member States can consider the values set out in Tables 1 and 2 as average values of the electrically driven heat pumps that have SPF above the minimum 2,5.