Division BAT-associated emission levels
United Kingdom
The BAT-AEL for channelled dust emissions from dusty operations (other than those from kiln firing, cooling and the main milling processes) is < 10 mg/Nm3, as the average over the sampling period (spot measurement, for at least half an hour).
It should be noted that for small sources (< 10 000 Nm3/h) a priority approach, based on the maintenance management system, regarding the frequency for checking the performance of the filter has to be taken into account (see also BAT 5).