Division BAT-associated emission levels
United Kingdom
The BAT-AEL for channelled dust emissions from dusty operations other than those from kiln firing processes is < 10 mg/Nm3, as daily average or average over the sampling period (spot measurements, for at least half an hour).
It should be noted that for small sources (< 10 000 Nm3/h) a priority approach, based on a maintenance management system regarding the frequency for checking the performance of the filter has to be taken into account (see BAT 55).
Notes on Division 59
Footnotes
- f1
-
A description of the techniques is provided in Section 1.7.1