OpenLegislation

Division BAT-associated emission levels

United Kingdom

Original text. Later amendments are not shown.

The BAT-AEL for channelled dust emissions from dusty operations other than those from kiln firing processes is < 10 mg/Nm3, as daily average or average over the sampling period (spot measurements, for at least half an hour).

It should be noted that for small sources (< 10 000 Nm3/h) a priority approach, based on a maintenance management system regarding the frequency for checking the performance of the filter has to be taken into account (see BAT 55).

Notes on Division 59

Footnotes

f1

A description of the techniques is provided in Section 1.7.1