Division 60
United Kingdom
In order to reduce dust emissions from the flue-gases of kiln firing processes, BAT is to use flue-gas cleaning with a filter by applying one or a combination of the following techniques:
| A description of the techniques is provided in Section 1.7.1. | ||
| Techniquef1 | Applicability | |
|---|---|---|
| a | Electrostatic precipitators (ESPs) | ESPs are mainly applicable in rotary kilns. They are applicable for flue-gas temperatures above the dew point and up to 370 – 400 °C |
| b | Fabric filters | Fabric filters for dust removal from flue-gases can, in principle, be applied for all units in the magnesium oxide manufacturing process. They can be used for flue-gas temperatures above the dew point and up to 280 °C. For the production of caustic calcined magnesia (CCM) and sintered/dead burned magnesia (DBM), due to the high temperatures, the corrosive nature and the high volume of the flue-gases occurring from the kiln firing process, special fabric filters with high temperature-resistant filter material have to be used. However, experience from the magnesia industry producing DBM shows that no suitable equipment is available for flue-gas temperatures of approximately 400 °C for magnesia production |
| c | Centrifugal separators/ cyclones | Because of the system-dependent limited degree of separation, cyclones are mainly applicable as preliminary separators for coarse dust and flue-gases |
| d | Wet dust separators | Generally applicable |
Annotations
Footnotes
- f1
-
A description of the techniques is provided in Section 1.7.1.