Division 6 Error in the CO2 savings due to the standard deviation (propagation law)
United Kingdom
The standard deviation of the efficiency value of the alternator (ΔηΑ), leads to an error in the CO2 savings. This error is to be calculated by means of the following formulaf1:
Formula (5)
Where:
ΔCO2 PRW PTA ηΑ–EI ΔηΑ VPe CF v
error in CO2 savings (g CO2/km);
750 W;
350 W;
Efficiency of the high efficient alternator;
Standard deviation of the efficiency of the alternator (result of equation in Formula (4);
Willans’ factors (l/kWh);
Conversion factors (g CO2/l);
mean driving speed of the NEDC (km/h)
Annotations
Footnotes
- f1
-
This formula (5) can be derived from the error propagation law which is explained in the Technical Guidelines (par. 4.2.1).