Division 2
United Kingdom
The apparatus shall be equipped with a probe of 5,95 mm diameter (and have abutting 6,3 mm of blade on either side of the probe at its head)containing a photodiode (Siemens LED of the type LYU 260-EO and photodetector of the type 58 MR) and having an operating distance of between 0 and 120 mm. The results of the measurements shall be transformed in terms of estimated lean meat content by means of the HGP 7 itself as well as a computer linked to it.