OpenLegislation

Division BAT 4 In order to reduce the generation and the pollution load of waste water from wood storage and preparation, BAT is to use a combination of the techniques given below.

United Kingdom

Original text. Later amendments are not shown.

TechniqueApplicability
aDry debarking (description see Section 1.7.2.1)Restricted applicability when high purity and brightness is required with TCF bleaching
bHandling of wood logs in such a way as to avoid the contamination of bark and wood with sand and stonesGenerally applicable
cPaving of the wood yard area and particularly the surfaces used for the storage of chipsApplicability may be restricted due to the size of the wood yard and storage area
dControlling the flow of sprinkling water and minimising surface run-off water from the wood yardGenerally applicable
eCollecting of contaminated run-off water from the wood yard and separating out suspended solids effluent before biological treatmentApplicability may be restricted by the degree of contamination of run-off water (low concentration) and/or the size of the waste water treatment plant (large volumes)

The BAT-associated effluent flow from dry debarking is 0,5 – 2,5 m3/ADt.