OpenLegislation

Division BAT 20 In order to reduce odour emissions and total reduced sulphur emissions due to strong and weak odorous gases, BAT is to prevent diffuse emissions by capturing all process-based sulphur containing off-gases, including all vents with sulphur-containing emissions, by applying all of the techniques given below.

United Kingdom

Original text. Later amendments are not shown.

The SOx emission levels of the lime kiln increase significantly when strong non-condensable gases (NCG) are fed to the kiln and no alkaline scrubber is used.

Applicable for the treatment of weak odorous gases.

Applicable for the treatment of strong odorous gases.

TechniqueDescription
a

Collection systems for strong and weak odorous gases, comprising the following features:

  • covers, suction hoods, ducts, and extraction system with sufficient capacity;

  • continuous leak detection system;

  • safety measures and equipment.

bIncineration of strong and weak non-condensable gases

Incineration can be carried out using:

  • recovery boiler

  • lime kilnf1

  • dedicated TRS burner equipped with wet scrubbers for SOx removal; or

  • power boilerf2

To ensure the constant availability of incineration for odorous strong gases, back-up systems are installed. Lime kilns can serve as back-up for recovery boilers; further back-up equipment are flares and package boiler

cRecording unavailability of the incineration system and any resulting emissionsf3
  1. Applicability

Annotations

Footnotes

f1

The SOx emission levels of the lime kiln increase significantly when strong non-condensable gases (NCG) are fed to the kiln and no alkaline scrubber is used.

f2

Applicable for the treatment of weak odorous gases.

f3

Applicable for the treatment of strong odorous gases.