OpenLegislation

Division BAT-associated emission levels

United Kingdom

Original text. Later amendments are not shown.

See Table 5.

Table 5

BAT-associated emission levels for dust emissions from a recovery boiler

For an existing recovery boiler equipped with an ESP approaching the end of its operational life, emission levels may increase over time up to 50 mg/Nm3 (corresponding to 0,4 kg/ADt).

ParameterDust abatement systemYearly averagemg/Nm3 at 6 % O2 Yearly averagekg dust/ADt
DustNew or major refurbishment10 – 250,02 – 0,20
Existing10 – 40f1 0,02 — 0,3

Annotations

Footnotes

f1

For an existing recovery boiler equipped with an ESP approaching the end of its operational life, emission levels may increase over time up to 50 mg/Nm3 (corresponding to 0,4 kg/ADt).