Division BAT-associated emission levels
United Kingdom
See Table 5.
Table 5
BAT-associated emission levels for dust emissions from a recovery boiler
For an existing recovery boiler equipped with an ESP approaching the end of its operational life, emission levels may increase over time up to 50 mg/Nm3 (corresponding to 0,4 kg/ADt). | |||
| Parameter | Dust abatement system | Yearly averagemg/Nm3 at 6 % O2 | Yearly averagekg dust/ADt |
|---|---|---|---|
| Dust | New or major refurbishment | 10 – 25 | 0,02 – 0,20 |
| Existing | 10 – 40f1 | 0,02 — 0,3 | |
Annotations
Footnotes
- f1
-
For an existing recovery boiler equipped with an ESP approaching the end of its operational life, emission levels may increase over time up to 50 mg/Nm3 (corresponding to 0,4 kg/ADt).