Division BAT 32 In order to increase the efficiency of power generation, BAT is to apply a combination of the techniques given below.

United Kingdom

Original text. Later amendments are not shown.

Technique
aHigh black liquor dry solid content (increases boiler efficiency, steam generation and thus electricity generation)
bHigh recovery boiler pressure and temperature; in new recovery boilers the pressure can be at least 100 bars and the temperature 510 °C
cOutlet steam pressure in the back-pressure turbine as low as technically feasible
dCondensing turbine for power production from excess steam
eHigh turbine efficiency
fPreheating feedwater to a temperature close to the boiling temperature
gPreheating the combustion air and fuel charged to the boilers