Division BAT-associated emission levels
United Kingdom
See Table 18 and Table 19.
The BAT-associated emission levels in Table 18 apply also to RCF without deinking pulp mills, and the BAT-associated emission levels in Table 19 apply also to RCF with deinking pulp mills.
The reference waste water flow for RCF mills is set out in BAT 5.
Table 18
BAT-associated emission levels for the direct waste water discharge to receiving waters from the integrated production of paper and board from recycled fibres pulp, produced without deinking on site
For mills with completely closed water circuits, there are no emissions of COD. | |
For existing plants, levels up to 0,45 kg/t may occur, due to the continuous decline in the quality of paper for recycling and the difficulty of continuously upgrading the effluent plant. | |
For mills with a waste water flow between 5 and 10 m3/t, the upper end of the range is 0,008 kg/t. | |
| Parameter | Yearly averagekg/t |
|---|---|
| Chemical oxygen demand (COD) | 0,4f1 – 1,4 |
| Total suspended solids (TSS) | 0,02 – 0,2f2 |
| Total nitrogen | 0,008 – 0,09 |
| Total phosphorus | 0,001 – 0,005f3 |
| Adsorbable organically bound halogens (AOX) | 0,05 for wet strength paper |
Table 19
BAT-associated emission levels for the direct waste water discharge to receiving waters from the integrated production of paper and board from recycled fibres pulp produced with deinking on site
| Parameter | Yearly averagekg/t |
|---|---|
| Chemical oxygen demand (COD) | 0,9 – 3,0 0,9 – 4,0 for tissue paper |
| Total suspended solids (TSS) | 0,08 – 0,3 0,1 – 0,4 for tissue paper |
| Total nitrogen | 0,01 – 0,1 0,01 – 0,15 for tissue paper |
| Total phosphorus | 0,002 – 0,01 0,002 – 0,015 for tissue paper |
| Adsorbable organically bound halogens (AOX) | 0,05 for wet strength paper |
The BOD concentration in the treated effluents is expected to be low (around 25 mg/l as a 24-hour composite sample).
Annotations
Footnotes
- f1
-
For mills with completely closed water circuits, there are no emissions of COD.
- f2
-
For existing plants, levels up to 0,45 kg/t may occur, due to the continuous decline in the quality of paper for recycling and the difficulty of continuously upgrading the effluent plant.
- f3
-
For mills with a waste water flow between 5 and 10 m3/t, the upper end of the range is 0,008 kg/t.