Division BAT 13 When further removal of organic substances or nitrogen is needed, BAT is to use an additional treatment step as described in Section 1.21.2.

United Kingdom

Original text. Later amendments are not shown.

Table 3

BAT-associated emission levels for direct waste water discharges from the refining of mineral oil and gas and monitoring frequencies associated with BAT f1

Not all parameters and sampling frequencies are applicable to effluent from gas refining sites.

Refers to a flow-proportional composite sample taken over a period of 24 hours or, provided that sufficient flow stability is demonstrated, a time-proportional sample.

Moving from the current method to EN 9377-2 may require an adaptation period.

Where on-site correlation is available, COD may be replaced by TOC. The correlation between COD and TOC should be elaborated on a case-by-case basis. TOC monitoring would be the preferred option because it does not rely on the use of very toxic compounds.

Where total-nitrogen is the sum of total Kjeldahl nitrogen (TKN), nitrates and nitrites.

When nitrification/denitrification is used, levels below 15 mg/l can be achieved.

ParameterUnitBAT-AEL(yearly average)Monitoringf2 frequency and analytical method (standard)
Hydrocarbon oil index (HOI)mg/l0,1-2,5

Daily

EN 9377- 2f3

Total suspended solids (TSS)mg/l5-25Daily
Chemical oxygen demand (COD)f4 mg/l30-125Daily
BOD5 mg/lNo BAT-AELWeekly
Total nitrogenf5, expressed as Nmg/l1-25f6 Daily
Lead, expressed as Pbmg/l0,005-0,030Quarterly
Cadmium, expressed as Cdmg/l0,002-0,008Quarterly
Nickel, expressed as Nimg/l0,005-0,100Quarterly
Mercury, expressed as Hgmg/l0,0001-0,001Quarterly
Vanadiummg/lNo BAT-AELQuarterly
Phenol Indexmg/lNo BAT-AEL

Monthly

EN 14402

Benzene, toluene, ethyl benzene, xylene (BTEX)mg/l

Benzene: 0,001-0,050

No BAT-AEL for T, E, X

Monthly

Annotations

Footnotes

f1

Not all parameters and sampling frequencies are applicable to effluent from gas refining sites.

f2

Refers to a flow-proportional composite sample taken over a period of 24 hours or, provided that sufficient flow stability is demonstrated, a time-proportional sample.

f3

Moving from the current method to EN 9377-2 may require an adaptation period.

f4

Where on-site correlation is available, COD may be replaced by TOC. The correlation between COD and TOC should be elaborated on a case-by-case basis. TOC monitoring would be the preferred option because it does not rely on the use of very toxic compounds.

f5

Where total-nitrogen is the sum of total Kjeldahl nitrogen (TKN), nitrates and nitrites.

f6

When nitrification/denitrification is used, levels below 15 mg/l can be achieved.