Division
United Kingdom
BAT-associated emission levels: See Table 4.
Table 4
BAT-associated emission levels for NOX emissions to air from the regenerator in the catalytic cracking process
| When antimony (Sb) injection is used for metal passivation, NOX levels up to 700 mg/Nm3 may occur. The lower end of the range can be achieved by using the SCR technique. | ||
| Parameter | Type of unit/combustion mode | BAT-AEL(monthly average)mg/Nm3 |
|---|---|---|
| NOX, expressed as NO2 | New unit/all combustion mode | < 30-100 |
| Existing unit/full combustion mode | < 100-300f1 | |
| Existing unit/partial combustion mode | 100-400 | |
The associated monitoring is in BAT 4.
- BAT 24Division BAT 24
- IPrimary or process-related techniques, such as:
- IISecondary or end-of-pipe techniques, such as:
Annotations
Footnotes
- f1
-
When antimony (Sb) injection is used for metal passivation, NOX levels up to 700 mg/Nm3 may occur. The lower end of the range can be achieved by using the SCR technique.