Division BAT 27 In order to reduce carbon monoxide (CO) emissions to air from the catalytic cracking process (regenerator), BAT is to use one or a combination of the techniques given below.
United Kingdom
| Technique | Description | Applicability |
|---|---|---|
| (i) Combustion operation control | See Section 1.20.5 | Generally applicable |
| (ii) Catalysts with carbon monoxide (CO) oxidation promoters | See Section 1.20.5 | Generally applicable only for full combustion mode |
| (iii) Carbon monoxide (CO) boiler | See Section 1.20.5 | Generally applicable only for partial combustion mode |
Notes on Division
Footnotes
- f1
-
May not be achievable when not operating the CO boiler at full load.