Division BAT 27 In order to reduce carbon monoxide (CO) emissions to air from the catalytic cracking process (regenerator), BAT is to use one or a combination of the techniques given below.

United Kingdom

Original text. Later amendments are not shown.

TechniqueDescriptionApplicability

(i)

Combustion operation control

See Section 1.20.5Generally applicable

(ii)

Catalysts with carbon monoxide (CO) oxidation promoters

See Section 1.20.5Generally applicable only for full combustion mode

(iii)

Carbon monoxide (CO) boiler

See Section 1.20.5Generally applicable only for partial combustion mode

Notes on Division

Footnotes

f1

May not be achievable when not operating the CO boiler at full load.