OpenLegislation

Division BAT 28 In order to reduce emissions of polychlorinated dibenzodioxins/furans (PCDD/F) to air from the catalytic reforming unit, BAT is to use one or a combination of the techniques given below.

United Kingdom

Original text. Later amendments are not shown.

TechniqueDescriptionApplicability

(i)

Choice of the catalyst promoter

Use of catalyst promoter in order to minimise polychlorinated dibenzodioxins/furans (PCDD/F) formation during regeneration.

See Section 1.20.7

Generally applicable
(ii) Treatment of the regeneration flue-gas

a.

Regeneration gas recycling loop with adsorption bed

Waste gas from the regeneration step is treated to remove chlorinated compounds (e.g. dioxins)

Generally applicable to new units.

For existing units the applicability may depend on the current regeneration unit design

b.

Wet scrubbing

See Section 1.20.3Not applicable to semi-regenerative reformers

c.

Electrostatic precipitator (ESP)

See Section 1.20.1Not applicable to semi-regenerative reformers