In order to prevent or reduce NOX emissions to air from the combustion units, BAT is to use one or a combination of the techniques given below.

Notes on Division

Footnotes

f1

BAT-AEL refers to combined emissions from the gas turbine and the supplementary firing recovery boiler, where present.

f2

For fuel with high H2 content (i.e. above 10 %), the upper end of the range is 75 mg/Nm3.

f3

For an existing unit using high air pre-heat (i.e. > 200 °C) or with H2 content in the fuel gas higher than 50 %, the upper end of the BAT-AEL range is 200 mg/Nm3.

f4

For existing units < 100 MW firing fuel oil with a nitrogen content higher than 0,5 % (w/w) or with liquid firing > 50 % or using air preheating, values up to 450 mg/Nm3 may occur.

f5

The lower end of the range can be achieved by using the SCR technique.