OpenLegislation

Division 3 The testing procedure

United Kingdom

Original text. Later amendments are not shown.

Measurements are to be performed as shown in the figure. The following equipment is to be used:

  • a power supply unit (i.e. variable voltage supplier),

  • two digital multi-meters, one for measuring the DC current, and the other for measuring the DC voltage. In the figure the test set-up shows the possible case of the DC voltage meter integrated in the power supply unit.

In total, five measurements on the current should be done at 13,2 V for each type of lighting used in the vehicle (i.e. low-beam headlamp, high-beam headlamp, front position, front fog, rear fog, front turn signal, rear turn signal, licence plate and reversing lamps). LED module(s) operated by an electronic light source control gear, shall be measured as specified by the applicant.

As an alternative, other measurements on the current can be done at other additional voltages. The manufacturer must hand over verified documentation on the necessity to perform these other measurements to the type-approval authority. In total, five measurements on the current are to be done at each of these additional voltages.

The exact installed voltages and the measured current are to be recorded in four decimals.

  1. Test set-up