Division Formula 4
United Kingdom
where:
Number of measurements of the sample, which is at least 5
The CO2-emission correction coefficient shall be determined from a set of T measurements performed by the manufacturer, as defined in Regulation UN/ECE No 101, Annex 8. For each measurement, the electricity balance during the test and the measured CO2-emissions shall be recorded.
In order to evaluate the statistical error of , all T combinations without repetitions of T-1 measurements has to be used to extrapolate T different values of (i.e. ). The extrapolation shall be performed according to the method defined in Regulation UN/ECE No 101, Annex 8.
The standard deviation of is thus calculated as defined by Formula 5.