OpenLegislation

Division Formula 5

United Kingdom

Original text. Later amendments are not shown.

S k CO 2 – = S k CO 2 T = ∑ t = 1 T k CO 2 t − k CO 2 – 2 T T − 1

where:

T
  • Number of measurements performed by the manufacturer for the extrapolation of the k CO 2 as defined in Regulation UN/ECE No 101, Annex 8

  • k CO 2 –
  • mean of the T values of k CO 2 t

  • The standard deviation of the power consumption of each efficient exterior LED light ( S P EI i – ) and the standard deviation of the k CO 2 S k CO 2 – lead to an error in the CO2 savings ( S C CO 2 ). This error is to be calculated by means of Formula 6.