Division BAT 26 In order to reduce dust and particulate-bound metal emissions to air from the combustion of solid biomass and/or peat, BAT is to use one or a combination of the techniques given below.

United Kingdom

Original text. Later amendments are not shown.

TechniqueDescriptionApplicability
a.Electrostatic precipitator (ESP)See description in Section 8.5Generally applicable
b.Bag filter
c.Dry or semi-dry FGD system

See descriptions in Section 8.5

The techniques are mainly used for SOX, HCl and/or HF control

d.Wet flue-gas desulphurisation (wet FGD)See applicability in BAT 25
e.Fuel choiceSee description in Section 8.5Applicable within the constraints associated with the availability of different types of fuel, which may be impacted by the energy policy of the Member State

Table 12

BAT-associated emission levels (BAT-AELs) for dust emissions to air from the combustion of solid biomass and/or peat

These BAT-AELs do not apply to plants operated < 1 500 h/yr.

For plants operated < 500 h/yr, these levels are indicative.

Combustion plant total rated thermal input(MWth)BAT-AELs for dust (mg/Nm3)
Yearly averageDaily average or average over the sampling period
New plantExisting plantf1 New plantExisting plantf2
< 1002–52–152–102–22
100–3002–52–122–102–18
≥ 3002–52–102–102–16

Annotations

Footnotes

f1

These BAT-AELs do not apply to plants operated < 1 500 h/yr.

f2