Table 13

BAT-associated energy efficiency levels (BAT-AEELs) for HFO and/or gas oil combustion in boilers

These BAT-AEELs do not apply to units operated < 1 500 h/yr.

In the case of CHP units, only one of the two BAT-AEELs ‘Net electrical efficiency’ or ‘Net total fuel utilisation’ applies, depending on the CHP unit design (i.e. either more oriented towards electricity generation or towards heat generation).

These levels may not be achievable if the potential heat demand is too low.

Type of combustion unitBAT-AEELsf1 f2
Net electrical efficiency (%)Net total fuel utilisation (%)f3
New unitExisting unitNew unitExisting unit
HFO- and/or gas-oil-fired boiler> 36,435,6–37,480–9680–96