Division BAT 29 In order to prevent or reduce SOX, HCl and HF emissions to air from the combustion of HFO and/or gas oil in boilers, BAT is to use one or a combination of the techniques given below.
United Kingdom
| Technique | Description | Applicability | |
|---|---|---|---|
| a. | Duct sorbent injection (DSI) | See description in Section 8.4 | Generally applicable |
| b. | Spray dry absorber (SDA) | ||
| c. | Flue-gas condenser | ||
| d. | Wet flue-gas desulphurisation (wet FGD) | There may be technical and economic restrictions for applying the technique to combustion plants of < 300 MWth. Not applicable to combustion plants operated < 500 h/yr. There may be technical and economic restrictions for retrofitting existing combustion plants operated between 500 h/yr and 1 500 h/yr | |
| e. | Seawater FGD | There may be technical and economic restrictions for applying the technique to combustion plants of < 300 MWth. Not applicable to combustion plants operated < 500 h/yr. There may be technical and economic restrictions for retrofitting existing combustion plants operated between 500 h/yr and 1 500 h/yr | |
| f. | Fuel choice | Applicable within the constraints associated with the availability of different types of fuel, which may be impacted by the energy policy of the Member State | |
Table 15
BAT-associated emission levels (BAT-AELs) for SO2 emissions to air from the combustion of HFO and/or gas oil in boilers
| These BAT-AELs do not apply to plants operated < 1 500 h/yr. | ||||
| For plants operated < 500 h/yr, these levels are indicative. | ||||
| For industrial boilers and district heating plants put into operation no later than 27 November 2003 and operated < 1 500 h/yr, the higher end of the BAT-AEL range is 400 mg/Nm3. | ||||
| The higher end of the BAT-AEL range is 175 mg/Nm3 for plants put into operation no later than 7 January 2014. | ||||
| For industrial boilers and district heating plants put into operation no later than 27 November 2003, which are operated < 1 500 h/yr and for which wet FGD is not applicable, the higher end of the BAT-AEL range is 200 mg/Nm3. | ||||
| Combustion plant total rated thermal input(MWth) | BAT-AELs for SO2 (mg/Nm3) | |||
|---|---|---|---|---|
| Yearly average | Daily average or average over the sampling period | |||
| New plant | Existing plantf1 | New plant | Existing plantf2 | |
| < 300 | 50–175 | 50–175 | 150–200 | 150–200f3 |
| ≥ 300 | 35–50 | 50–110 | 50–120 | 150–165f4 f5 |
Annotations
Footnotes
- f1
-
These BAT-AELs do not apply to plants operated < 1 500 h/yr.
- f2
-
For plants operated < 500 h/yr, these levels are indicative.
- f3
-
For industrial boilers and district heating plants put into operation no later than 27 November 2003 and operated < 1 500 h/yr, the higher end of the BAT-AEL range is 400 mg/Nm3.
- f4
-
The higher end of the BAT-AEL range is 175 mg/Nm3 for plants put into operation no later than 7 January 2014.
- f5
-
For industrial boilers and district heating plants put into operation no later than 27 November 2003, which are operated < 1 500 h/yr and for which wet FGD is not applicable, the higher end of the BAT-AEL range is 200 mg/Nm3.