Division BAT 40 In order to increase the energy efficiency of natural gas combustion, BAT is to use an appropriate combination of the techniques given in BAT 12 and below.

United Kingdom

Original text. Later amendments are not shown.

TechniqueDescriptionApplicability
a.Combined cycleSee description in Section 8.2

Generally applicable to new gas turbines and engines except when operated < 1 500 h/yr.

Applicable to existing gas turbines and engines within the constraints associated with the steam cycle design and the space availability.

Not applicable to existing gas turbines and engines operated < 1 500 h/yr.

Not applicable to mechanical drive gas turbines operated in discontinuous mode with extended load variations and frequent start-ups and shutdowns.

Not applicable to boilers

Table 23

BAT-associated energy efficiency levels (BAT-AEELs) for the combustion of natural gas

These BAT-AEELs do not apply to units operated < 1 500 h/yr.

In the case of CHP units, only one of the two BAT-AEELs ‘Net electrical efficiency’ or ‘Net total fuel utilisation’ applies, depending on the CHP unit design (i.e. either more oriented towards electricity generation or heat generation).

Net total fuel utilisation BAT-AEELs may not be achievable if the potential heat demand is too low.

These BAT-AEELs do not apply to plants generating only electricity.

These BAT-AEELs apply to units used for mechanical drive applications.

These levels may be difficult to achieve in the case of engines tuned in order to reach NOX levels lower than 190 mg/Nm3.

Type of combustion unitBAT-AEELsf1 f2
Net electrical efficiency (%)Net total fuel utilisation (%)f3 f4 Net mechanical energy efficiency (%) f5
New unitExisting unitNew unitExisting unit
Gas engine39,5–44f6 35–44 56–85 No BAT-AEEL.
Gas-fired boiler39–42,538–4078–95No BAT-AEEL.
Open cycle gas turbine, ≥ 50 MWth36–41,533–41,5No BAT-AEEL36,5–4133,5–41
Combined cycle gas turbine (CCGT)
CCGT, 50–600 MWth 53–58,546–54No BAT-AEELNo BAT-AEEL
CCGT, ≥ 600 MWth 57–60,550–60No BAT-AEELNo BAT-AEEL
CHP CCGT, 50–600 MWth 53–58,546–5465–95No BAT-AEEL
CHP CCGT, ≥ 600 MWth 57–60,550–6065–95No BAT-AEEL

Annotations

Footnotes

f1

These BAT-AEELs do not apply to units operated < 1 500 h/yr.

f2

In the case of CHP units, only one of the two BAT-AEELs ‘Net electrical efficiency’ or ‘Net total fuel utilisation’ applies, depending on the CHP unit design (i.e. either more oriented towards electricity generation or heat generation).

f3

Net total fuel utilisation BAT-AEELs may not be achievable if the potential heat demand is too low.

f4

These BAT-AEELs do not apply to plants generating only electricity.

f5

These BAT-AEELs apply to units used for mechanical drive applications.

f6

These levels may be difficult to achieve in the case of engines tuned in order to reach NOX levels lower than 190 mg/Nm3.