Division BAT 46 In order to increase the energy efficiency of the combustion of iron and steel process gases, BAT is to use an appropriate combination of the techniques given in BAT 12 and below.
United Kingdom
| Technique | Description | Applicability | |
|---|---|---|---|
| a. | Process gas management system | See description in Section 8.2 | Only applicable to integrated steelworks |
Table 27
BAT-associated energy efficiency levels (BAT-AEELs) for the combustion of iron and steel process gases in boilers
| These BAT-AEELs do not apply in the case of units operated < 1 500 h/yr. | ||
| In the case of CHP units, only one of the two BAT-AEELs ‘Net electrical efficiency’ or ‘Net total fuel utilisation’ applies, depending on the CHP unit design (i.e. either more oriented towards electricity generation or towards heat generation). | ||
| These BAT-AEELs do not apply to plants generating only electricity. | ||
| The wide range of energy efficiencies in CHP units is largely dependent on the local demand for electricity and heat. | ||
| Type of combustion unit | BAT-AEELsf1 f2 | |
|---|---|---|
| Net electrical efficiency (%) | Net total fuel utilisation (%)f3 | |
| Existing multi-fuel firing gas boiler | 30–40 | 50–84 |
| New multi-fuel firing gas boilerf4 | 36–42,5 | 50–84 |
Table 28
BAT-associated energy efficiency levels (BAT-AEELs) for the combustion of iron and steel process gases in CCGTs
| These BAT-AEELs do not apply in the case of units operated < 1 500 h/yr. | |||
| In the case of CHP units, only one of the two BAT-AEELs ‘Net electrical efficiency’ or ‘Net total fuel utilisation’ applies, depending on the CHP unit design (i.e. either more oriented towards electricity generation or towards heat generation). | |||
| These BAT-AEELs do not apply to plants generating only electricity. | |||
| Type of combustion unit | BAT-AEELsf5 f6 | ||
|---|---|---|---|
| Net electrical efficiency (%) | Net total fuel utilisation (%)f7 | ||
| New unit | Existing unit | ||
| CHP CCGT | > 47 | 40–48 | 60–82 |
| CCGT | > 47 | 40–48 | No BAT-AEEL |
Annotations
Footnotes
- f1
-
These BAT-AEELs do not apply in the case of units operated < 1 500 h/yr.
- f2
-
In the case of CHP units, only one of the two BAT-AEELs ‘Net electrical efficiency’ or ‘Net total fuel utilisation’ applies, depending on the CHP unit design (i.e. either more oriented towards electricity generation or towards heat generation).
- f3
-
These BAT-AEELs do not apply to plants generating only electricity.
- f4
-
The wide range of energy efficiencies in CHP units is largely dependent on the local demand for electricity and heat.
- f5
-
These BAT-AEELs do not apply in the case of units operated < 1 500 h/yr.
- f6
-
In the case of CHP units, only one of the two BAT-AEELs ‘Net electrical efficiency’ or ‘Net total fuel utilisation’ applies, depending on the CHP unit design (i.e. either more oriented towards electricity generation or towards heat generation).
- f7
-
These BAT-AEELs do not apply to plants generating only electricity.