Division BAT 58 In order to reduce emissions to air of dust, particulate-bound metals, and trace species from the combustion of process fuels from the chemical industry in boilers, BAT is to use one or a combination of the techniques given below.
United Kingdom
| Technique | Description | Applicability | |
|---|---|---|---|
| a. | Electrostatic precipitator (ESP) | See descriptions in Section 8.5 | Generally applicable |
| b. | Bag filter | ||
| c. | Fuel choice | See description in Section 8.5. Use of a combination of process fuels from the chemical industry and auxiliary fuels with a low averaged dust or ash content | Applicable within the constraints associated with the availability of different types of fuel and/or an alternative use of the process fuel |
| d. | Dry or semi-dry FGD system | See descriptions in Section 8.5. The technique is mainly used for SOX, HCl and/or HF control | See applicability in BAT 57 |
| e. | Wet flue-gas desulphurisation (wet FGD) | ||
Table 37
BAT-associated emission levels (BAT-AELs) for dust emissions to air from the combustion of mixtures of gases and liquids composed of 100 % process fuels from the chemical industry in boilers
| For plants operated < 1 500 h/yr, these BAT-AELs do not apply. | ||||
| For plants operated < 500 h/yr, these levels are indicative. | ||||
| For plants put into operation no later than 7 January 2014, the higher end of the BAT-AEL range is 25 mg/Nm3. | ||||
| For plants put into operation no later than 7 January 2014, the higher end of the BAT-AEL range is 15 mg/Nm3. | ||||
| Combustion plant total rated thermal input(MWth) | BAT-AELs for dust (mg/Nm3) | |||
|---|---|---|---|---|
| Yearly average | Daily average or average over the sampling period | |||
| New plant | Existing plantf1 | New plant | Existing plantf2 | |
| < 300 | 2–5 | 2–15 | 2–10 | 2–22f3 |
| ≥ 300 | 2–5 | 2–10f4 | 2–10 | 2–11 |
Annotations
Footnotes
- f1
-
For plants operated < 1 500 h/yr, these BAT-AELs do not apply.
- f2
-
For plants operated < 500 h/yr, these levels are indicative.
- f3
-
For plants put into operation no later than 7 January 2014, the higher end of the BAT-AEL range is 25 mg/Nm3.
- f4
-
For plants put into operation no later than 7 January 2014, the higher end of the BAT-AEL range is 15 mg/Nm3.