OpenLegislation

Division 10.1.1 BAT-AEL for emissions to air from an EDC cracker furnace

United Kingdom

Original text. Later amendments are not shown.

Table 10.1

BAT-AELs for emissions to air of NOX from an EDC cracker furnace

Where the flue-gases of two or more furnaces are discharged through a common stack, the BAT-AEL applies to the combined discharge from the stack.

The BAT-AELs do not apply during decoking operations.

No BAT-AEL applies for CO. As an indication, the CO emission level will generally be 5–35 mg/Nm3 expressed as a daily average or an average over the sampling period.

ParameterBAT-AELsf1 f2 f3(daily average or average over the sampling period)(mg/Nm3, at 3 vol-% O2)
NOx 50–100

The associated monitoring is in BAT 1.

Annotations

Footnotes

f1

Where the flue-gases of two or more furnaces are discharged through a common stack, the BAT-AEL applies to the combined discharge from the stack.

f2

The BAT-AELs do not apply during decoking operations.

f3

No BAT-AEL applies for CO. As an indication, the CO emission level will generally be 5–35 mg/Nm3 expressed as a daily average or an average over the sampling period.