Division 10.1.1 BAT-AEL for emissions to air from an EDC cracker furnace
United Kingdom
Table 10.1
BAT-AELs for emissions to air of NOX from an EDC cracker furnace
| Where the flue-gases of two or more furnaces are discharged through a common stack, the BAT-AEL applies to the combined discharge from the stack. | |
| The BAT-AELs do not apply during decoking operations. | |
| No BAT-AEL applies for CO. As an indication, the CO emission level will generally be 5–35 mg/Nm3 expressed as a daily average or an average over the sampling period. | |
| Parameter | BAT-AELsf1 f2 f3(daily average or average over the sampling period)(mg/Nm3, at 3 vol-% O2) |
|---|---|
| NOx | 50–100 |
The associated monitoring is in BAT 1.
Annotations
Footnotes
- f1
-
Where the flue-gases of two or more furnaces are discharged through a common stack, the BAT-AEL applies to the combined discharge from the stack.
- f2
-
The BAT-AELs do not apply during decoking operations.
- f3
-
No BAT-AEL applies for CO. As an indication, the CO emission level will generally be 5–35 mg/Nm3 expressed as a daily average or an average over the sampling period.